STOVEMASTER - Custom Design and Construction of Masonry Heaters
Contact Alex Chernov,
Certified Heater Mason
Member of MHA
WETT#8347
Tel. (519) 938-9166
Cell (416) 708-8139
alex.chernov@stovemaster.com
Testing at Lopez Lab Ontario


Summary of test results using different firebox systems in the same double-bell heater.


Test ID PM g/kg Stack T(F) O2 % CO % Eff. Condar % Eff. Testo %
TL-001 1,11 276 14,6 0,1730 73 75 Workshop test. Hot heater, DRY SLOT, SECONDARY AIR (all outlets open)
TL-002 1,34 202 14,5 0,2058 77 81 * problems with Magnehelic. PM number is not correct.
DRY SLOT.NO SECONDARY AIR.
TL-003 0.54* 266 15,2 0,1659 70 73
TL-004 1,67 223 14,2 0,3388 74 78
TL-005 0,98 223 13,9 0,1990 77 80
TL-006 0,62 214 12,3 0,2797 79 83 NO DRY SLOT. NO SECODNARY AIR.
TL-007 0,45 255 14,7 0,1576 75 78
TL-008 0,60 203 14,0 0,1563 79 80
TL-009 0,61 227 15,2 0,1073 76 79 DRY SLOT. Secondary air according to Igor Kuznetsov
TL-010 1,35 200 15,7 0,1500 76 78
TL-011 1,35 262 14,8 0,1973 73 76
TL-012 1,36 206 14,2 0,1429 78 82 4.5" high DRY SLOT at the bottom. NO SECONDARY AIR.
TL-013 0,66 230 14,4 0,1895 76 79 NO DRY SLOT. NO SECODNARY AIR.


Sep25_2009 TL-001
Sep25_2009 TL-001

Nov8_2009 TL-002
Nov8_2009 TL-002

Nov18_2009 TL-003
Nov18_2009 TL-003

Nov20_2009 TL-004
Nov20_2009 TL-004

Dec06_2009 TL-005
Dec06_2009 TL-005

Dec25-2009 TL-006
Dec25-2009 TL-006

Dec26_2009 TL-007
Dec26_2009 TL-007

Dec28_2009 TL-008
Dec28_2009 TL-008

Dec30-2009 TL-009
Dec30-2009 TL-009

Jan03_2001 TL-010
Jan03_2001 TL-010

Jan16-2010 TL-011
Jan16-2010 TL-011